CRBH12025A cross roller bearing / CRBHV12025A has a 120 × 180 × 25 mm envelope. For an inspection stage, define the working diameter and measurement datums before agreeing accuracy. LYDL provides the corresponding matched IKO equivalent, with the bearing inspection distinguished from the runout of a customer flange.
Or email sales@luoyangdeeplink.com
CRBH12025A cross roller bearing / CRBHV12025A has a 120 mm bore, 180 mm outside diameter and 25 mm width. This envelope suits a rotary-stage assessment where a 100 mm opening has become restrictive and the machine can accept an additional 5 mm of bearing width. A larger opening is useful only when the shaft and retaining arrangement preserve the space that the application needs.
The IKO reference lists 73.4 kN basic dynamic radial rating, 108 kN basic static radial rating and 2.62 kg mass. These figures establish a defined selection starting point. They do not state the accuracy of a finished inspection stage or the payload that a complete machine may carry.
Review related stage envelopes in the series selection guide and follow the CRBH / CRBHV category for the associated product group.

Ordering the CRBH12025A / CRBHV12025A cross roller bearing? Send the drawing, the complete replacement reference or the required quantity. LYDL confirms the matched configuration, inspection scope and export terms in the quotation.
| Parameter | Value | Unit |
|---|---|---|
| Bore diameter d | 120 | mm |
| Outside diameter D | 180 | mm |
| Bearing width B | 25 | mm |
| Minimum chamfer rmin | 1 | mm |
| Inner-ring shoulder reference da | 132 | mm |
| Outer-ring shoulder reference Da | 168 | mm |
| Basic dynamic radial rating Cr | 73.4 | kN |
| Basic static radial rating C0r | 108 | kN |
| Reference bearing mass | 2.62 | kg |
These catalogue values establish an envelope and load reference, not a micrometre runout result for an inspection stage. The 2.62 kg mass also contributes to moving inertia. Specify the measuring datum and approved interfaces independently from the bearing load assessment.
The reference design uses integrated inner and outer rings with crossed cylindrical rollers. IKO identifies POM separators for CRBHV. For CRBH12025A, preserve the specified internal arrangement when matching an existing reference; the absence of V alone does not prove a universal metal-separator construction.
Runout must be associated with a surface, a datum and a measurement condition. Bearing-level radial or axial running accuracy differs from the reading taken on a large customer flange. Decide which result is the acceptance requirement before selecting the accuracy specification for the order.
Open and sealed arrangements also affect inspection conditions. Specify the intended lubricant, seal state and clearance or preload when rotational resistance matters. These details prevent a torque reading from being compared against a result obtained on a differently configured bearing.
Reference construction: catalogue [1] and product guide [2].
An inspection table may be checked near its centre during assembly and near its outer edge during use. Those readings need not be identical. Record the actual measurement diameter, probe direction and reference surface so the test describes the part of the stage that matters to the process.
The shoulder references are da 132 mm and Da 168 mm, with a 1 mm minimum bearing chamfer reference. Review the adjoining corners and retaining contact against the approved drawing. A housing fillet must clear the bearing rather than push it away from the intended seating face.
A mounting plate that appears flat on a bench may change shape once it is bolted into the machine. Assess plate thickness, support beneath the bearing and the effect of tightening. Where the assembly accuracy is demanding, distinguish the loose-component inspection from the final installed check.
An indexing cycle and a stationary measuring period impose different conditions. Provide acceleration, dwell and any process load applied after positioning. The bearing assessment should consider the complete cycle while the accuracy test should use the agreed operating state.
Moving from 10020A to 12025A increases bore from 100 to 120 mm, outside diameter from 150 to 180 mm and width from 20 to 25 mm. Reference mass rises from 1.45 to 2.62 kg. This changes the mechanical package and moving inertia, so it deserves a fresh mounting and drive review.
15025A retains 25 mm width and the same calculated 30 mm radial section while enlarging the opening to 150 mm. If measurement access is the main reason for changing size, compare the complete fixture openings first. An RU mounting concept is another option when fixing holes simplify a new stage design.
| Size reference | Bore d (mm) | OD D (mm) | Width B (mm) |
|---|---|---|---|
| CRBH10020A / CRBHV10020A | 100 | 150 | 20 |
| CRBH15025A / CRBHV15025A | 150 | 210 | 25 |
For a stage with a new fastening layout, RU178, 115 × 240 × 28 mm has a similar bore range but a substantially different outer footprint. Compare the RU ring-fixing design against instrument access and the available mounting area.
Rotary inspection stages: specify the working diameter and instrument datum. A bearing report should support the stage acceptance plan without being presented as proof of the finished machine accuracy.
Machine-tool positioning: distinguish forces during indexing from forces applied during a stopped process. Include the fixture overhang and the way the stage is supported.
Semiconductor carrier positioning: describe the workpiece support, lubricant restrictions and local environment. A standard reference designation does not establish vacuum suitability or cleanliness by itself.
Laboratory rotary fixtures: consider access for sensors, specimen holders and cleaning tools. The application image illustrates relevant equipment categories rather than documenting an installed 12025A customer unit.
Application-family background: reference [3].

A useful inspection request separates three items: bearing boundary dimensions, bearing running accuracy and assembled-stage performance. State which ring is the datum and which surface is measured for each check. This makes supplier and receiving results easier to compare.
The dimensional identification is 120 × 180 × 25 mm. If a flange reading is also required, include its diameter and attachment condition. Different fixture restraint can change a result, so compare measurements only after the setup and acceptance limits have been aligned.
Protect the inspected faces during packing and identify each carton with the full reference. For a crated order, secure individual units against movement without loading the precision rings. The 2.62 kg catalogue mass is a bearing reference; cartons, protection and the outer crate add to the shipment weight.

The bearing envelope changes from 100 × 150 × 20 mm to 120 × 180 × 25 mm. Shaft size, housing diameter, retaining components and moving mass all change. Review the full stage drawing instead of treating the larger bearing as a capacity-only upgrade.
A reading on a customer flange depends on where and how it is taken. Give the measurement diameter, probe direction and datum so the result can be reproduced. This also distinguishes the application target from the bearing-level accuracy specification.
Flatness is only part of the requirement. The plate must also remain sufficiently rigid under fastening and operating loads. Check its thickness, support and retaining contact, then inspect the assembly in the condition that represents its intended use.
Yes. Acceleration acts during movement, while measuring or process forces may act during a stationary dwell. State both parts of the cycle, including load positions. This gives the selection review a clearer duty description than average speed alone.
It answers a different question. A flange measurement includes attachment, machining and mounting effects as well as the bearing contribution. Keep the component inspection and final-stage acceptance requirements distinct so responsibility and test conditions remain clear.
Request a 12025A quotation with the assembly section, complete replacement designation, required quantity and destination. For inspection equipment, add the working diameter, datum surfaces, motion cycle and acceptance limits. Specify the records needed for receiving inspection and whether they concern the bearing or the finished customer fixture. The quotation should confirm the matched configuration and the agreed scope of documentation.
IKO is its owner’s trademark. LYDL supplies its own branded equivalent, matched to the complete reference configuration; the technical comparison does not imply IKO manufacture or endorsement.
Brand Alternatives: THK · IKO · INA · Kaydon