Assess an offset payload by resolving the loads at the slewing bearing reference plane: axial force, radial force and overturning moment. Include the payload, rotating structure and relevant process or motion forces in each simultaneous load case. Then review the bearing, mounting connection, support structure and drive using the data applicable to the proposed configuration.
A payload mass alone cannot identify a suitable slewing bearing. The same mass can create a different overturning moment when its centre of gravity moves, and a bearing-capacity check does not by itself approve the fixing bolts or supporting frame.
Establish the axis and reference plane first
Draw the rotation axis, bearing reference plane and locations where forces act. Use the same coordinate system for the application drawing and the supplier's load assessment.
For a vertical-axis table, gravity commonly contributes axial force. A centre of gravity offset from the axis also creates an overturning moment. A horizontal process force applied above the bearing plane can add radial force and another overturning moment.
For a horizontal or inclined axis, resolve the forces again. A load component called axial in one orientation does not retain that meaning after the reference axis changes.
Distinguish overturning moment from torque about the driven rotation axis. The first tends to tilt the bearing position; the second acts around its rotation axis. A drive calculation and a bearing-support calculation therefore need clearly identified components.
Convert mass to force before calculating the moment
For a static gravity load, force is mass multiplied by gravitational acceleration. For a force F with a perpendicular moment arm e, the moment magnitude is:
M = F × e
The following is an arithmetic illustration for a vertical-axis arrangement. It is not an LYDL capacity rating, customer installation or completed selection. Assume a 200 kg payload and use g = 9.81 m/s².
| Assumed payload | Gravity force | Perpendicular offset | Payload moment |
|---|---|---|---|
| 200 kg | 1,962 N | 0.25 m | 490.5 N·m |
| 200 kg | 1,962 N | 0.75 m | 1,471.5 N·m |
The axial gravity force is unchanged, while the payload moment triples. This is why replacing a load description such as 200 kg with a complete force-and-position record matters.
Use consistent units. A value of 490.5 N·m is 0.4905 kN·m; confusing those units changes the reported moment by a factor of one thousand.
Add the rotating structure and process forces
The fixture and supporting parts above the bearing also contribute loads. Use their actual masses and centres of gravity rather than adding a general percentage to the payload.
Extend the illustration with a 40 kg fixture at a 0.10 m offset and a horizontal 100 N process force at a height of 0.30 m above the reference plane. Assume the three moment vectors act in the same overturning direction during this one static instant.
| Assumed contribution | Force | Moment arm | Overturning contribution |
|---|---|---|---|
| Payload gravity | 1,962 N | 0.25 m | 490.50 N·m |
| Fixture gravity | 392.4 N | 0.10 m | 39.24 N·m |
| Horizontal process force | 100 N | 0.30 m | 30.00 N·m |
For this simplified instant, the gravity-related axial force is 2,354.4 N, the radial force is 100 N, and the combined overturning moment is 559.74 N·m, approximately 0.560 kN·m.
These are simultaneous components of one assumed case. They exclude acceleration, other loads and application factors. In the real model, use vector directions and signs; moment contributions can reinforce or oppose each other.
Do not combine the greatest axial force from one operating position with a moment from an unrelated position and call that the measured working condition. If a conservative design envelope is used, identify it explicitly and agree how it enters the assessment.
Build more than one operating load case
The static calculation is only the starting point. Different stages can govern different parts of the design.
| Operating case | Information to include |
|---|---|
| Holding an offset load | Payload, fixture mass, centre of gravity and orientation |
| Rotation and positioning | Motion profile, inertia, load position and simultaneous forces |
| Process operation | Cutting, handling, clamping or other external forces and positions |
| Reversal or braking | Specified motion and the resulting reactions |
| Exceptional event | Defined event, loads and applicable assessment method |
| Transport or installation | Temporary support and handling conditions, if relevant |
The machine designer should define the applicable events. A generic shock factor does not replace an explanation of the equipment's actual duty.
For repeated operation, provide load history and the number or duration of cycles. A static limiting-load check and an assessment of repeated operation answer different questions; passing one does not automatically complete the other.
Read the correct bearing data with its conditions
Use the load diagram and calculation method for the exact proposed bearing. Establish the meaning of each axis, the required load factors and the supported mounting assumptions before plotting a case.
Rothe Erde's technical guidance treats bearing selection and load factors as defined parts of the application assessment. Its diagrams and methods belong to the referenced products; they should not be transferred to an LYDL model as though they were LYDL test results. Technical reference: slewing bearing selection
Ask which data apply to the candidate in the LYDL slewing bearing range. Identify the complete model and rolling-contact arrangement. A family designation or outside diameter alone cannot supply an allowable overturning moment.
If a required rating or curve is unavailable, keep it as an unresolved selection input. Do not estimate a permissible moment by multiplying a catalogue force rating by an assumed diameter without an approved method.

Check the connection and supporting structure separately
A suitable bearing still depends on its installed load path. Review how reactions reach the mounting faces, fixing bolts, supporting ring and machine frame.
Rothe Erde highlights the need for a rigid companion structure and properly designed connecting bolts. Its guidance explains that the bearing's relatively small section relies on the surrounding structure to control deformation. Technical reference: companion structure
For the LYDL installation, identify support contact, mounting geometry, joint requirements and the assessment for the chosen connection. Do not interpret a bearing load curve as approval of an arbitrary bolt pattern or flexible plate.
The review should include where ribs or walls carry the reactions and how access for controlled fixing is maintained. Mounting flatness and bolt preload requirements must come from the matching installation and joint specification.
Keep gearing and drive loads in the review
Where the slewing bearing incorporates gearing, define pinion location, driven torque, operating cycle and the associated gear forces. The gear mesh and drive introduce their own design requirements alongside the bearing-support loads.
Compare the complete geared arrangement rather than assuming a bearing that passes a raceway assessment also meets tooth-strength, backlash or drive requirements. Use the actual gear data and installation drawing.
LYDL's catalogue includes several slewing-bearing families. Shortlist the construction and interface suited to the application, then request the corresponding load and connection data. Do not treat all entries as the same internal structure with different diameters.
For example, the LYDL VU130225 entry identifies a four-point contact ball slewing bearing. That identifies a construction to investigate; it does not make the model a recommendation for the assumed 200 kg example. Its own load data, mounting arrangement and operating limits would still be needed.
Send a load-case sheet that can be assessed
| Enquiry field | What to provide |
|---|---|
| Layout | Axis orientation, bearing plane, mounting section and fixed interfaces |
| Forces | Axial/radial components with coordinates and signs |
| Moments | Overturning components and drive-axis torque identified separately |
| Load sources | Payload, fixture, rotating parts and process forces |
| Duty | Speed, accelerations, motion angles, durations and repeated cycles |
| Support and joint | Contact geometry, supporting structure and fixing arrangement |
| Gear arrangement | Internal/external or ungeared requirement, drive data and pinion layout |
| Verification | Required load assessment, displacement and inspection scope |
The table is a record template, not a test report. Attach a labelled drawing so the force application points can be interpreted without guessing.
Slewing Bearing Moment Load FAQs
How do I calculate the overturning moment from an offset payload?
For a static gravity load on a vertical-axis table, calculate M = m × g × e, using payload mass m in kg, gravitational acceleration g in m/s² and the horizontal centre-of-gravity offset e in m; the result is in N·m. Add simultaneous moment components from fixtures and process forces using their directions and signs at the bearing reference plane. This gives the applied load, not the bearing’s allowable moment.
Why can the same payload lead to a different slewing bearing selection?
Moving the centre of gravity changes the moment arm even when the payload mass stays the same. In the illustrative 200 kg example above, increasing the offset from 0.25 m to 0.75 m triples the payload’s gravity-induced moment. Whether a different bearing is required depends on the complete simultaneous load case, operating duty and the exact candidate’s applicable load data.
Is overturning moment the same as drive torque?
No. Overturning moment tends to tilt the bearing about an axis perpendicular to the rotation axis, while drive torque acts about the intended rotation axis. Both can be expressed in N·m, but they must be identified as separate components when reviewing bearing support, gearing and drive requirements.
Does passing the bearing load check also approve the bolts and supporting structure?
No. A passing raceway-capacity check does not establish that the fixing bolts, joints or machine frame are suitable. Review the complete load path, support rigidity, mounting faces and specified bolt preload using the matching drawing and installation or joint requirements.
What information should I send LYDL for a slewing bearing selection review?
Send a labelled mounting section and the simultaneous axial-force, radial-force and overturning-moment components, with their directions and force application points. Include the payload and fixture masses and centres of gravity, speed or oscillation cycle, support and fixing layout, any gear-drive data, and the required displacement or accuracy checks. If a candidate model has already been chosen, include its full designation and drawing.
Discuss the complete bearing position with LYDL
For background on the construction, see the LYDL slewing bearing overview. Use the current slewing bearing catalogue to identify a candidate family, then send LYDL the load-case sheet and mounting section.
A useful enquiry describes the load and its position, not only the mass to be carried. It gives the bearing, fixing connection, support and drive a common set of conditions for evaluation.